Mechanistic Investigation and Prevention of Al Bond Pad Corrosion in Cu Wire Bonded Device Assembly

  • Authors:
    Oliver Chyan (Univ. of North Texas)
    Publication ID:
    P091075
    Publication Type:
    Annual Review
    Received Date:
    5-Jun-2017
    Last Edit Date:
    20-Jun-2017
    Research:
    2665.001 (University of North Texas)

Abstract

Heavy corrosion on aluminum (Al) bond pads, with a “mud-crack” appearance, in a copper (Cu) wire-bonded assembly can be a critical failure mode, especially under harsh conditions such as automotive environments. This corrosion can be associated with the presence of contaminants such as chloride ions (Cl-). However, the exact corrosion activation mechanism remains unclear and hence the effective corrosion prevention cannot be achieved. In this report, a novel immersion corrosion screening metrology was utilized as an in situ characterization tool to establish the corrosion mechanism directly relevant to Cu wire-bonded devices. With this improved understanding of Al bond pad corrosion mechanism, severe Al pad corrosion can be prevent with a corrosion inhibitor coating. The corrosion inhibitor coating remains stable at 260 oC annealing. Preliminary failure analysis on molded devices showed corrosion inhibitor coating is highly effective in prevent chloride related Al pad corrosion.

Past Events

  Event Summary
13 June 2017
GRC
GRC
Packaging Review
Tuesday, June 13, 2017, 8 a.m.–5 p.m. ET
Atlanta, GA, United States